The UviCure Plus II is a single band radiometer with the EIT Band and Dynamic Range specified at the time of order. The Power Puck II is a four band radiometer with the Dynamic Range specified at the time of order.
——
UviCure® Plus II
EIT UviCure Plus II
UVICURE® Plus II
The UviCure Plus II is a single band radiometer with the EIT Band and Dynamic Range specified at the time
of order. The Power Puck II is a four band radiometer with the Dynamic Range specified at the time of order.
The UviCure Plus II oversample at an extremely high rate. The user is able to adjust the
effective sample rate used for data collection. For most applications, we recommend the Smooth Profiler
setting.
• Smooth On: Effective sample rate of 25 Hz (samples per second), matches obsolete Power Puck units
• Smooth Profiler: Effective sample rate of 128 Hz, suggested rate for most applications. The Smooth
Profiler setting reports the average (RMS) peak intensity.
• Smooth Off: Effective sample rate of 2048 Hz. Fast enough to detect the AC cycling in a 50/60 Hz power
supply. Reports the instantaneous irradiance value which is higher than the RMS value.
Display | Easy to Read, Yellow Text on Black Background |
Suggested Operating Ranges | Standard High Range: UVA, UVB, UVV - 100mW/cm² to 10W/cm² / UVC - 10mW/cm² to 1W/cm² Mid-Range: UVA, UVB, UVV -10mW/cm2 to 1W/cm2 / UVC: 1mW/cm2 to100mW /cm2 Low Power: UVA, UVB, UVV - 1mW/cm² to 100mW/cm² / UVC - 1mW/cm2 to 100mW/cm2 The suggested Operating Ranges are where the instrument performs best. Units will “turn on” and dis-play data at irradiance values much lower than the suggested Operating Ranges. |
Accuracy | +/- 10%; +/- 5% typical plus ±0.2% of full scale Typical +/- 5% or better |
Calibration | Supplied with NIST traceable calibration certificate |
Spectral Ranges (UVICURE® Plus II) | One channel monitoring of UVA (320-390 nm), UVB (280-320nm) , UVC (250-260nm) or UVV (395-445nm) , selected at the time of purchase |
Spatial Response | Approximately cosine, “Lambertian” |
Operating Temperature | 0-75°C Internal temperature; tolerates high external temperatures for short periods (audible alarm indi-cates when temperature has exceeded tolerance) |
Smooth Modes | Smooth ON: Effective Sample rate of 25 samples/second Smooth PROFILER: Effective Sample rate of 128 samples/second Smooth OFF: Effective Sample rate of 2048 samples/second |
Time-Out Period | 2 minutes DISPLAY mode (no key activity) |
Battery/Battery Life | Two user-replaceable AAA Alkaline Cells/Approximately 20 hours with the display “on” |
Dimensions | 4.60 x 0.50 inches; 117 mm x 12.7 mm (D x H) |
Weight | 10.1 ounces (289 grams) |
Instrument Materials | Aluminum, stainless steel |
Carrying Case Material/Weight | Cut polyurethane interior, scuff resistant nylon exterior cover/9 ounces (260 grams) |
Carrying Case Dimensions | 10.75 x 3.5 x 7.75 inches; 274 x 89 x 197 mm (W x H x D) |
2025-06
UVICURE® Plus IIDisplayEasy to Read, Yellow Text on Black BackgroundSuggested Operating Ranges Standard High Range: UVA, UVB, UVV - 100mW/c…… [了解更多]
2018-03
美国IET UVICURE PLUS II能量计可测试UVA UVB UVC UVV四个波段之中的一个波段的UV能量和UV光强度。… [了解更多]